Features

Full interactive grid inverter

Including an AC source with double disconnection relay with the grid. This input complies with the latest grid-tied regulations in the UE and other regions.

Also available in 120Vac and UL compliant

The next1 will have 120Vac output version meeting the UL standards (coming soon).

Solar AC

The next1 works smoothly with solar inverters coupled both on the AC loads and/or AC flex ports.

Battery compatibility

The next1 incorporates our flexible battery profile options, compatible with lead-acid and Li-ion batteries. Ask our team for other battery technologies.

Rack 19” ready

The next1 rack version is available for 19” professional rack and batteries integration.

AC flex

The unique AC flex interface can be configured as a second source or an extra controlled load.

Power flow dispatcher®, the brain of the whole system

System oriented, the power flow dispatcher® centralizes the power management of the complete system integrally.

nextOS, the gate to the powerful next ecosystem

nextOS is an intuitive smart platform to configure, control and analyse your system. Making life easier for both professional installers and final users.



nx1 6000-48nx1 6000-48 US

Inverter

Continuous power @25°C4 000 VA4 000 VA
Power 30 min. @25°C6 000 VA6 000 VA
Power 3 sec. @25°CNYA
Nominal line to neutral output voltagepure sine wave 220/230/240 Vac (±1%)Pure sine wave 110/120/130 Vac (±1%)
Nominal output frequency50/60 Hz (±0.02%)60/50 Hz (±0.02%)
Loads cosφ range0.1 – 1
Harmonic distorsion (THD)< 1%

Battery charger

Nominal battery voltage (Input range)48 Vdc (38 – 68 Vdc)
Maximum charging current / power*110Adc / NYA
Charge characteristic

6 steps: bulk, absorption, floating, equalization, reduced floating, periodic absorption

Temperature compensation

with nx tempsensor (included)

Cos φ 0.1-1 | Harmonic distortion < 1 % | Charge characteristic* 6 steps: bulk, absorption, floating, equalization, reduced floating, periodic absorption | Temperature compensation* with nx tempsensor (included)

AC source (*Grid or Genset)

Maximum rated current90 Aac
Operating line to neutral voltage range176 – 288 Vac
Nominal line to neutral voltage220 / 230 / 240 Vac
Nominal frequency*50 / 60 Hz
Overvoltage category (OVC)III
Grid code compliance*

EU Commission Regulation 2016/631 (NC RfG), EN 50549-1:2019, VDE-AR-N 4105:2018, IEC 62116, IEC 61727

AC flex (*Controlled 2nd AC load or Genset)

Maximum rated current50 Aac
Operating line to neutral voltage range176 – 288 Vac60 – 150 Vac
Nominal line to neutral voltage220 / 230 / 240 Vac110 / 120 / 130 Vac
Nominal frequency50 / 60 Hz60 / 50 Hz

General data

5 to 95 % (non condensing)

Product dimensions h/w/l and weight175 / 420 / 550 mm 35 kg
Transport dimensions h/w/l and weightNYA
Selfconsumption OFF / Standby / ON3 / 7 / 20 W
I/O Communications2 x nx communication bus RJ45/8, 1 x CAN BMS, 1 x RS485i (Modbus), 1 x nx tempSensor
Multifunction I/O contacts2 x digital Input, 2 x analogical Input, 2 x Output, rating 16 A each
Interfacesnx interface, datalogger USB 1-min resolution, 1 x RS485i, 1 x LAN, 2 x USB, nx wifidongle, studer portal + easy monitoring App
Safety+EMC conformity (CE marking)EU Low Voltage Directive (LVD) 2014/35/EU, EU Electromagnetic Compliance (EMC) 2014/30/EU
Ingress Protection according to IEC60529IP 54

Operating ambient temperature range -20 to 55°C | Relative humidity operation range 5 to 95 % (non condensing) | Mounting location Indoor, unconditioned

Data may change without any notice. | *Adjustable values